Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1959 1
1960 1
1963 4
1964 4
1966 3
1967 2
1968 4
1969 1
1970 5
1971 2
1972 2
1973 3
1974 9
1975 8
1976 2
1977 2
1978 5
1979 2
1980 1
1981 3
1982 6
1983 6
1984 2
1985 2
1986 13
1987 9
1988 4
1989 5
1990 17
1991 18
1992 16
1993 19
1994 22
1995 14
1996 12
1997 17
1998 17
1999 16
2000 30
2001 57
2002 57
2003 67
2004 48
2005 73
2006 93
2007 87
2008 106
2009 101
2010 88
2011 112
2012 114
2013 114
2014 129
2015 108
2016 103
2017 112
2018 127
2019 136
2020 143
2021 144
2022 143
2023 129
2024 52

Text availability

Article attribute

Article type

Publication date

Search Results

2,410 results

Results by year

Filters applied: . Clear all
Page 1
Bioreactor scale-up and oxygen transfer rate in microbial processes: an overview.
Garcia-Ochoa F, Gomez E. Garcia-Ochoa F, et al. Biotechnol Adv. 2009 Mar-Apr;27(2):153-76. doi: 10.1016/j.biotechadv.2008.10.006. Epub 2008 Nov 12. Biotechnol Adv. 2009. PMID: 19041387 Review.
In aerobic bioprocesses, oxygen is a key substrate; due to its low solubility in broths (aqueous solutions), a continuous supply is needed. ...Many studies have been conducted to enhance the efficiency of oxygen transfer. The dissolved oxygen concentration in …
In aerobic bioprocesses, oxygen is a key substrate; due to its low solubility in broths (aqueous solutions), a continuous supply is n …
Air Versus Oxygen in ST-Segment-Elevation Myocardial Infarction.
Stub D, Smith K, Bernard S, Nehme Z, Stephenson M, Bray JE, Cameron P, Barger B, Ellims AH, Taylor AJ, Meredith IT, Kaye DM; AVOID Investigators. Stub D, et al. Circulation. 2015 Jun 16;131(24):2143-50. doi: 10.1161/CIRCULATIONAHA.114.014494. Epub 2015 May 22. Circulation. 2015. PMID: 26002889 Free article. Clinical Trial.
METHODS AND RESULTS: We conducted a multicenter, prospective, randomized, controlled trial comparing oxygen (8 L/min) with no supplemental oxygen in patients with ST-elevation-myocardial infarction diagnosed on paramedic 12-lead ECG. ...There was a significant incre …
METHODS AND RESULTS: We conducted a multicenter, prospective, randomized, controlled trial comparing oxygen (8 L/min) with no supplem …
Oxygen transport across tank-treading red blood cell: Individual and joint roles of flow convection and oxygen-hemoglobin reaction.
Amiri FA, Zhang J. Amiri FA, et al. Microvasc Res. 2023 Jan;145:104447. doi: 10.1016/j.mvr.2022.104447. Epub 2022 Oct 19. Microvasc Res. 2023. PMID: 36270419
In this study, we consider a tank-treading capsule in shear flow, which is generated with two parallel plates moving in opposite directions: the top plate of a higher oxygen pressure (P(O(2))) representing the RBC core in the central region of a microvessel and the …
In this study, we consider a tank-treading capsule in shear flow, which is generated with two parallel plates moving in opposite dire …
Chemical oxygen generation.
Ward KR, Huvard GS, McHugh M, Mallepally RR, Imbruce R. Ward KR, et al. Respir Care. 2013 Jan;58(1):184-95. doi: 10.4187/respcare.01983. Respir Care. 2013. PMID: 23271828 Free article.
While pressurized oxygen in tank form, as well as oxygen concentrators, are ubiquitous in civilian healthcare in developed countries for medical use, there are a number of settings where use of these oxygen delivery platforms is problematic. ...This pa …
While pressurized oxygen in tank form, as well as oxygen concentrators, are ubiquitous in civilian healthcare in develo …
Mobility profiles of patients with home oxygen therapy.
Díaz Lobato S, Mayoralas Alises S. Díaz Lobato S, et al. Arch Bronconeumol. 2012 Feb;48(2):55-60. doi: 10.1016/j.arbres.2011.10.002. Epub 2011 Nov 30. Arch Bronconeumol. 2012. PMID: 22133712 Review. English, Spanish.
Home oxygen therapy has been classically based on the use of compressed oxygen cylinders and portable oxygen (O(2)) concentrators. ...Proper indication for home oxygen therapy, the selection of the right source and the titration of the oxygen fl …
Home oxygen therapy has been classically based on the use of compressed oxygen cylinders and portable oxygen (O(2)) con …
Evaluation of oxygen transfer rates in stirred-tank bioreactors for clinical manufacturing.
Bellucci JJ, Hamaker KH. Bellucci JJ, et al. Biotechnol Prog. 2011 Mar-Apr;27(2):368-76. doi: 10.1002/btpr.540. Epub 2011 Jan 7. Biotechnol Prog. 2011. PMID: 21485030
To be practically useful, mass transfer measurements made in nonfermenting systems must be consistent with observed microbial respiration rates. This report details a procedure for quantifying the relationship between agitation frequency and oxygen transfer rate tha …
To be practically useful, mass transfer measurements made in nonfermenting systems must be consistent with observed microbial respiration
Evaluation of Over-the-Counter Portable Oxygen Concentrators Utilizing a Metabolic Simulator.
Casaburi R, Hess M, Porszasz J, Clark W, Diesem R, Tal-Singer R, Ferguson C. Casaburi R, et al. Respir Care. 2023 Apr;68(4):445-451. doi: 10.4187/respcare.10495. Epub 2022 Nov 18. Respir Care. 2023. PMID: 36400446 Free PMC article.
RESULTS: Continuous-flow tank oxygen yielded a linear P(ETO(2)) increase as flow increased, with progressively lower slope of increase for higher metabolic rate. ...CONCLUSIONS: Only one of 3 OTC POCs tested was potentially of use by patients requiring ambulatory …
RESULTS: Continuous-flow tank oxygen yielded a linear P(ETO(2)) increase as flow increased, with progressively lower slope of …
Microbioreactor Systems for Accelerated Bioprocess Development.
Hemmerich J, Noack S, Wiechert W, Oldiges M. Hemmerich J, et al. Biotechnol J. 2018 Apr;13(4):e1700141. doi: 10.1002/biot.201700141. Epub 2018 Jan 25. Biotechnol J. 2018. PMID: 29283217 Review.
They provide a unique solution to combine higher experimental throughput with extensive bioprocess monitoring and control, which is indispensable to develop economically and ecologically competitive bioproduction processes. MBR systems are based either on down-scaled stirred t
They provide a unique solution to combine higher experimental throughput with extensive bioprocess monitoring and control, which is indispen …
[The effect of husbandry shortcomings on oxygen supply in pet fish tanks].
Mieske P, Hetz SK. Mieske P, et al. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2020 Apr;48(2):89-98. doi: 10.1055/a-1122-7861. Epub 2020 Apr 23. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2020. PMID: 32325524 German.
Quantitative changes in oxygen partial pressure were measured in the tank as well as in a simplified model tank. RESULTS: Oxygen uptake rate of the tank (substrate, aquatic plants, bacteria, reduced substances) was not quantifiable in the experi …
Quantitative changes in oxygen partial pressure were measured in the tank as well as in a simplified model tank. RESULT …
2,410 results